3 projects for internal protection of tanks. View the technical data!
In the following lines you can see the corrosion protection systems that have been applied inside the tanks, produced by one of the top competitors in the European market. The measures are designed to maintain long-term quality of the steel structure for many types of aggressive substances storage tanks.
Project nr.1
Double-wall steel tank for underground storage
Volume: 80 m³ (devided in 2 x 25 m³ and 3 x 10 m³), diameter 2,9 m
Coating Product: Proguard CN-OC
Layer Thickness: 800 µm, applied in 2 layers by airless spraying
Product Requirements: Extreme chemical resistance
Project nr.2
Double-wall steel stank for overground storage of methanol/ethanol
Volume: 30 m³, diameter 2 m
Coating Product: Proguard CN 200 a.s.
Layer Thickness: 600 µm, applied in 2 layers by airless spraying
Product Requirements: High chemical resistance, antistatic properties
Project nr.3
Storage tank for water
Volume: 4 m³, diameter 1,6 m
Coating Product: Proguard CN 200
Layer Thickness: 1.000 µm, applied in 2 layers by airless spraying
Product Requirements: Pressure resistance (max. 6 bar), temperature stability (max. 110°C)
If you need a specialized team for applying chemical resistant coating, contact us! We guarantee that you will have the benefit of an applicantion process that meets all standards.